Emergency Medical Interventional Technologies...where minutes translate into life or death.
HypothermX™ - HX100

HypothermX™ - LG

HypothermX™ HX100 is a patent protected portable fluid warming device designed to warm intravenous fluids, blood or blood products infused into a patient to prevent or treat trauma, environmental, procedure related and/or induced hypothermia. Heating is accomplished via a flameless hydrocarbon combustion process fueled with a isobutane/propane mixture.
HypothermX™ HX100 is the first truly light weight (< 3.0 lbs), portable, long-term (>4 hours continuous use) solution to offer actual therapeutic warming in the field for injured patients. HypothermX™ HX100 is capable of warming up to 5 liters of saline introduced at 15° C and 15 units of packed red blood cells introduced at 5° C to 38° C ± 3° C with an infusion rate between 50 ml/min and 200 ml/min and ambient conditions between 0° C and 40° C. The system has numerous safety features and provides the user with the ability to temporarily silence alarms based on operational needs.
HypothermX™ LG is the first truly light weight (1 lbs), portable, acute (1 hours continuous use) solution to offer actual therapeutic warming in the field for injured patients. HypothermX™ LG is capable of warming up to 2 liters of saline introduced at 15° C and 2 units of packed red blood cells introduced at 5° C to 38° C ± 3° C with an infusion rate between 50 ml/min and 100 ml/min and ambient conditions between 0° C and 40° C. The system has numerous safety features and provides the user with the ability to temporarily silence alarms based on operational needs.
| HypothermX™ - HX100 Features |
|
| Infusion Flow Rates | 50-200 ml/minute |
| Infusion Quantity & Temperature | 5 liter of saline at 15° C and 15 units of packed red blood cells at 5° C |
| Ambient Conditions | 0°C - 40°C, non-condensing humidity 30% - 95% |
| Output Temperature/Set-Point | 38±3°C |
| Time to Achieve Set-Point | ˂ 1 minute (reference 5° C packed red blood cells infused at 100 ml/min) |
| Heating Method | Conduction via Aluminum Heat Exchanger |
| Heating Source | Flameless Catalytic Combustion |
| Fuel | Isobutane/Propane Mixture |
| Temperature Control | Precision Thermistors |
| Electronics | Microprocessor Controlled |
| Alarms | Audio & Visual LED Indicators |
| Safety Features | Independent Temperature Cutoffs |
| Power Source | Lithium Sulfur Dioxide Battery |
| Dimensions | 9.5” x 5.4” x 2.4” |
| Weight | 2.8 lbs |
| Use | Disposable |
| HypothermX™ - LG Features |
|
| Infusion Flow Rates | 50-100 ml/minute |
| Infusion Quantity & Temperature | 2 liter of saline at 15° C and 2 units of packed red blood cells at 5° C |
| Ambient Conditions | 0°C - 40°C, non-condensing humidity 30% - 95% |
| Output Temperature/Set-Point | 38±3°C |
| Time to Achieve Set-Point | ˂ 1 minute (reference 5° C packed red blood cells infused at 100 ml/min) |
| Heating Method | Conduction via Aluminum Heat Exchanger |
| Heating Source | Flameless Catalytic Combustion |
| Fuel | Isobutane/Propane Mixture |
| Temperature Control | Precision Thermistors |
| Electronics | Microprocessor Controlled |
| Alarms | Audio & Visual LED Indicators |
| Safety Features | Independent Temperature Cutoffs |
| Power Source | Lithium Sulfur Dioxide Battery |
| Dimensions | 7.0” x 3.0” x 1.5” |
| Weight | 1 lbs |
| Use | Disposable |
U.S. Patent No. 7,261,557 and other Patents Pending
US Federal Law restricts this device to sale by, or on order of, a physician or any other practitioner licensed by the law of the state in which he or she practices to use or order the use of this device.
HypothermX™ and EMIT Corporation™ are trademarks of EMIT Corporation™.
Copyright © 2011 -2016 EMIT CORPORATION. All rights reserved.